Viessmann · Boiler · Vitodens 100-W WB1B series
WB1B 35c (CombiPLUS Kit 7459 305) parts
38 replacement parts that fit the Viessmann WB1B 35c (CombiPLUS Kit 7459 305), with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Cover panel | 010 | 1 | |
| Bottom panel | 020 | 1 | |
| Nipple, HEX | 101 | 1 | c in. (fraction glyph garbled in source) |
| Flex pipe, c in. x 7 in. | 102 | 1 | c in. x 7 in. (fraction glyph garbled) |
| Flex pipe, c in. x 12 in. | 103 | 1 | c in. x 12 in. (fraction glyph garbled) |
| Connectors, set of 2 with clips and O-rings | 104 | set of 2 | |
| Sealing grommet | 105 | 1 | |
| Accessory pack, anchors | 106 | set of 4 | |
| Pressure relief valve | 107 | 1 | 150 psig (size fraction garbled) |
| Tee, brass | 108 | 1 | c in. (fraction glyph garbled) |
| Gaskets, assortment | 109 | 1 | b in., c in. (fraction glyphs garbled) |
| Adaptor, G x NPT male | 110 | 1 | G c in. female x NPT c in. male (glyphs garbled) |
| Adaptor, G female x NPT male | 111 | 1 | G b in. female x NPT b in. male (glyphs garbled) |
| Harness for sensors | 200 | 1 | |
| Harness for pump | 201 | 1 | |
| Accessory pack, conduit clips | 202 | set of 2 | |
| Installation fittings (items 101 to 111 and 390, complete set) Listed under other parts, not illustrated. | 100 | complete set | |
| Installation / Service Instructions | 400 | 1 | |
| Quick Start-up Guide | 401 | 1 | |
| Parts List | 402 | 1 | |
| Installation Template | 403 | 1 | |
| Touch-up spray paint "Vitowhite" | 404 | 1 | |
| Touch-up paint stick "Vitowhite" | 405 | 1 | |
| Accessory pack, plugs, clips and O-rings | 323 | 1 | Clips 340 and 344, plus O-rings |
| Replacement powerhead | 330 | 1 | UPS15-78, 115/1/60 |
| Plate heat exchanger | 331 | 1 | 20 plates |
| Gasket set, PWT | 332 | 1 | |
| Step motor, linear | 333 | 1 | |
| Flow sensor | 334 | 1 | |
| Air vent | 335 | 1 | |
| Bypass cartridge | 337 | 1 | |
| Clip d=8, set of 5 | 339 | set of 5 | d=8 |
| Clip d=10, set of 5 | 340 | set of 5 | d=10 |
| Clip d=16, set of 5 | 342 | set of 5 | d=16 |
| Clip SIV special, set of 5 | 344 | set of 5 | |
| Expansion pipe | 348 | 1 | |
| Sensor #3 boiler | 383 | 1 | |
| Diverter valve assembly | 392 | 1 |
Same series
The Vitodens 100-W WB1B parts list shows every part for all 6 models side by side. Other models: WB1B 26, WB1B 26c, WB1B 35, WB1B-26, WB1B-35.
Source: Vitodens 100-W WB1B installation and service manual, p. 96 (pages 96, 97). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.