Rinnai · Boiler parts
Rinnai I-Series Plus: parts list
93 replacement parts with OEM part numbers for 1 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Scale Cutter filter assembly Filters and reduces scale entering the boiler. | 103000038 | I-Series Plus | 1 | |
| Scale Cutter refill cartridge Refill cartridge for the Scale Cutter filter assembly. | 103000039 | I-Series Plus | 1 | |
| DHW isolation valve kit Quick isolation of the boiler DHW connections. | MIVK-T-LW | I-Series Plus | 1 | |
| Primary-secondary heating kit | 807000212 | I-Series Plus | 1 | |
| DHW temperature controller | MC-601 | I-Series Plus | 1 | |
| Cascade cable, 10 ft / 3 m | REU-CSA-C1 | I-Series Plus | 1 | 10 ft / 3 m |
| Cascade cable, 26 ft / 8 m | REU-CSA-C2 | I-Series Plus | 1 | 26 ft / 8 m |
| Condensate neutralizer Neutralizes the condensate produced by the boiler. | 804000074 | I-Series Plus | 1 | |
| Natural gas to propane conversion kit Boiler ships set for natural gas only. Kit converts to propane. | 807000211 | I-Series Plus | 1 | |
| 2/4 Condensing Horizontal Term Kit 8.7 in. 2 in./4 in. concentric direct vent | 229011NPP | I-Series Plus | 1 | Equivalent length 5 ft |
| 2/4 Condensing Horizontal Term Kit 12 in. 2 in./4 in. concentric direct vent | 229012NPP, 229031 | I-Series Plus | 1 | Equivalent length 5 ft |
| 2/4 Condensing Horizontal Term Kit 21 in. 2 in./4 in. concentric direct vent | 229013NPP, 229032 | I-Series Plus | 1 | Equivalent length 5 ft |
| 2/4 Condensing Roof Discharge Termination 20 in. above roof 2 in./4 in. concentric direct vent | 224356NPP, 224359 | I-Series Plus | 1 | Equivalent length 5 ft |
| 2/4 Condensing 90 Degree Diverter Nose (use with wall terminal) Use with wall terminal | 710202NPP | I-Series Plus | 1 | Equivalent length 5 ft |
| 2/4 Condensing 45 Degree Diverter Nose (use with wall terminal) Use with wall terminal | 710215NPP | I-Series Plus | 1 | Equivalent length 5 ft |
| FGV Concentric Vent Kit (16 in. length) Alternate PVC kit ordered from Rinnai Replaces / alternate: 196005PVC (order from Rinnai). | 196005, 197040 | I-Series Plus | 1 | Equivalent length 20 ft |
| FGV Concentric Vent Kit (28 in. length) Alternate PVC kit ordered from Rinnai Replaces / alternate: 196105PVC (order from Rinnai). | 196105, 197033 | I-Series Plus | 1 | Equivalent length 20 ft |
| FGV Concentric Vent Kit (40 in. length) Alternate PVC kit ordered from Rinnai Replaces / alternate: 196125PVC (order from Rinnai). | 196125 | I-Series Plus | 1 | Equivalent length 20 ft |
| PVC Concentric Vent Kit 2 in. x 16 in. 2 in./4 in. concentric | 52CVKGVS6502 | I-Series Plus | 1 | Equivalent length 20 ft |
| PVC Concentric Vent Kit 2 in. x 28 in. 2 in./4 in. concentric | 52CVKGVS6502-28 | I-Series Plus | 1 | Equivalent length 20 ft |
| PVC Concentric Vent Kit 2 in. x 40 in. 2 in./4 in. concentric | 52CVKGVS6502-40 | I-Series Plus | 1 | Equivalent length 20 ft |
| 2 in. x 4 in. Concentric Roof Termination 2 in./4 in. concentric | ICRT2439 | I-Series Plus | 1 | Equivalent length 20 ft |
| 2 in. x 4 in. Vertical Termination Cap Kit-Concentric 2 in./4 in. concentric | 2PPS-VKL/VK-TCL | I-Series Plus | 1 | Equivalent length 20 ft |
| 2 in. x 4 in. Horizontal Termination Kit-Concentric 2 in./4 in. concentric | 2PPS-HKL | I-Series Plus | 1 | Equivalent length 20 ft |
| 2 in. x 4 in. Concentric Horizontal Termination 2 in./4 in. concentric | 190288 | I-Series Plus | 1 | Equivalent length 5 ft |
| 2 in. x 4 in. Concentric Vertical Termination 2 in./4 in. concentric | 190295 | I-Series Plus | 1 | Equivalent length 5 ft |
| 2 in. x 4 in. Concentric Horizontal Termination 2 in./4 in. concentric | CVENT-2 | I-Series Plus | 1 | Equivalent length 20 ft |
| 2 in. x 4 in. Concentric Horizontal Termination 2 in./4 in. concentric | 2ZDCTH24 | I-Series Plus | 1 | Equivalent length 5 ft |
| 2 in. x 4 in. Concentric Roof Termination 2 in./4 in. concentric | 2ZDCTV24 | I-Series Plus | 1 | Equivalent length 5 ft |
| 3/5 Condensing Horizontal Term Kit 8.7 in. 3 in./5 in. concentric direct vent | 223174PP | I-Series Plus | 1 | Equivalent length 5 ft |
| 3/5 Condensing Horizontal Term Kit 12 in. 3 in./5 in. concentric direct vent | 223176PP | I-Series Plus | 1 | Equivalent length 5 ft |
| 3/5 Condensing Horizontal Term Kit 21 in. 3 in./5 in. concentric direct vent | 223177PP | I-Series Plus | 1 | Equivalent length 5 ft |
| 3/5 Condensing Horizontal Diverter Termination Kit 19 in. 3 in./5 in. concentric direct vent | 223186PP | I-Series Plus | 1 | Equivalent length 16 ft |
| 3/5 Condensing Raised Horizontal Termination Kit 3 in./5 in. concentric direct vent | 224047PP | I-Series Plus | 1 | Equivalent length 24 ft |
| 3/5 Condensing Roof Discharge Termination 20 in. above roof 3 in./5 in. concentric direct vent | 184162PP | I-Series Plus | 1 | Equivalent length 5 ft |
| FGV Concentric Vent Kit 3 in. x 20 in. 3 in./5 in. concentric Replaces / alternate: 196006PVC (order from Rinnai). | 196006, 197009 | I-Series Plus | 1 | Equivalent length 20 ft |
| FGV Concentric Vent Kit 3 in. x 32 in. 3 in./5 in. concentric Replaces / alternate: 196106PVC (order from Rinnai). | 196106, 197107 | I-Series Plus | 1 | Equivalent length 20 ft |
| FGV Concentric Vent Kit 3 in. x 44 in. 3 in./5 in. concentric Replaces / alternate: 196116PVC (order from Rinnai). | 196116, 197117 | I-Series Plus | 1 | Equivalent length 20 ft |
| PVC/CPVC Concentric Vent Kit 3 in. x 20 in. 3 in./5 in. concentric | 52CVKGVS6503 (PVC) / 52CVKGVSF9003 (CPVC) | I-Series Plus | 1 | Equivalent length 20 ft |
| PVC/CPVC Concentric Vent Kit 3 in. x 32 in. 3 in./5 in. concentric | 52CVKGVS6503-32 (PVC) / 52CVKGVSF9003-32 (CPVC) | I-Series Plus | 1 | Equivalent length 20 ft |
| PVC/CPVC Concentric Vent Kit 3 in. x 44 in. 3 in./5 in. concentric | 52CVKGVS6503-44 (PVC) / 52CVKGVSF9003-44 (CPVC) | I-Series Plus | 1 | Equivalent length 20 ft |
| Horizontal Termination Adapter 3 in./5 in. concentric | SC03HT | I-Series Plus | 1 | Equivalent length 20 ft |
| Vertical Termination Adapter 3 in./5 in. concentric | SC03VT | I-Series Plus | 1 | Equivalent length 20 ft |
| 3/5 Concentric Roof Termination PPs-UV 3 in./5 in. concentric | ICRT3539 | I-Series Plus | 1 | Equivalent length 20 ft |
| 3/5 Condensing Horizontal Termination Kit 8.7 in Equivalent length not clear in extraction | 223174PP | All 1 models | 1 | |
| 3/5 Condensing Horizontal Termination Kit 12 in Equivalent length not clear in extraction | 223176PP | All 1 models | 1 | |
| 3/5 Condensing Horizontal Termination Kit 21 in | 223177PP | All 1 models | 1 | 5 ft equivalent length (probable) |
| 3/5 Condensing Horizontal Diverter Termination Kit 19 in | 223186PP | All 1 models | 1 | 16 ft equivalent length |
| 3/5 Condensing Raised Horizontal Termination Kit | 224047PP | All 1 models | 1 | 24 ft equivalent length |
| 3/5 Condensing Roof Discharge Termination 20 in above roof | 184162PP | All 1 models | 1 | 5 ft equivalent length |
| FGV Concentric Vent Kit 3 in x 20 in PVC version 196006PVC, order from Rinnai Replaces / alternate: 197009. | 196006 | All 1 models | 1 | 20 ft equivalent length |
| FGV Concentric Vent Kit 3 in x 32 in PVC version 196106PVC, order from Rinnai Replaces / alternate: 197107. | 196106 | All 1 models | 1 | 20 ft equivalent length |
| FGV Concentric Vent Kit 3 in x 44 in PVC version 196116PVC, order from Rinnai Replaces / alternate: 197117. | 196116 | All 1 models | 1 | 20 ft equivalent length |
| PVC/CPVC Concentric Vent Kit 3 in x 20 in Replaces / alternate: 52CVKGVSF9003 (CPVC). | 52CVKGVS6503 | All 1 models | 1 | 20 ft equivalent length |
| PVC/CPVC Concentric Vent Kit 3 in x 32 in Replaces / alternate: 52CVKGVSF9003-32 (CPVC). | 52CVKGVS6503-32 | All 1 models | 1 | 20 ft equivalent length |
| PVC/CPVC Concentric Vent Kit 3 in x 44 in Replaces / alternate: 52CVKGVSF9003-44 (CPVC). | 52CVKGVS6503-44 | All 1 models | 1 | 20 ft equivalent length |
| Horizontal Termination Adapter | SC03HT | All 1 models | 1 | 20 ft equivalent length |
| Vertical Termination Adapter | SC03VT | All 1 models | 1 | 20 ft equivalent length |
| 3/5 in Concentric Roof Termination PPs-UV | ICRT3539 | All 1 models | 1 | 20 ft equivalent length |
| 3 in x 5 in Vertical Adapter | 3CGRLSV | All 1 models | 1 | 1 ft equivalent length |
| 3 in x 5 in Horizontal Adapter | 3CGRLSH | All 1 models | 1 | 6 ft equivalent length |
| 3 in x 5 in Vertical Termination | 3CGRVT | All 1 models | 1 | 5 ft equivalent length |
| 3 in x 5 in Horizontal Termination | 3CGRHT | All 1 models | 1 | 16 ft equivalent length |
| 3 in x 5 in Vertical Termination Cap Kit-Concentric | 3PPS-VKL/VK-TCL | All 1 models | 1 | 20 ft equivalent length |
| 3 in x 5 in Horizontal Termination Kit-Concentric | 3PPS-HKL | All 1 models | 1 | 20 ft equivalent length |
| 3 in x 5 in Concentric Horizontal Termination | 190388 | All 1 models | 1 | 5 ft equivalent length |
| 3 in x 5 in Concentric Vertical Termination | 190395 | All 1 models | 1 | 5 ft equivalent length |
| 3 in x 5 in Concentric Horizontal Termination | CVENT-3 | All 1 models | 1 | 20 ft equivalent length |
| 3 in x 5 in Concentric Horizontal Termination | 2ZDCTH35 | All 1 models | 1 | 5 ft equivalent length |
| 3 in x 5 in Concentric Roof Termination | 2ZDCTV35 | All 1 models | 1 | 5 ft equivalent length |
| 2 in 87 degree Long PPS-UV | ISELL0287UV | All 1 models | 1 | 6 ft equivalent length |
| 2 in Termination Tee | ISTT0220 | All 1 models | 1 | 6 ft equivalent length |
| 2 in Low Profile Wall Termination | ISLPT0202 | All 1 models | 1 | 5 ft equivalent length |
| 2 in Twin Pipe Termination | 2PPS-HTPL | All 1 models | 1 | 10 ft equivalent length |
| 2 in Single Horizontal Termination | 2PPS-HSTL | All 1 models | 1 | 6 ft equivalent length |
| 2 in Black UV Resistant Tee | 2PPS-TBL | All 1 models | 1 | 5 ft equivalent length |
| FGV PVC Low Profile Termination Kit PVC version 196984PVC, order from Rinnai | 196984 | All 1 models | 1 | 5 ft equivalent length |
| FGV PVC Wall Termination Kit | 081216 | All 1 models | 1 | 16 ft equivalent length |
| PVC Side Wall Vent Kit | 52SWVKGVS6502 | All 1 models | 1 | 5 ft equivalent length |
| PVC Wall Vent Kit | 52WTVKGVS6502 | All 1 models | 1 | 16 ft equivalent length |
| 2 in Low Profile Horizontal Vent Kit | HVENT-2 | All 1 models | 1 | 5 ft equivalent length |
| 3 in 87 degree Long PPS-UV | ISELL0387UV | All 1 models | 1 | 6 ft equivalent length |
| 3 in Termination Tee | ISTT0320 | All 1 models | 1 | 6 ft equivalent length |
| 3 in Low Profile Wall Termination | ISLPT0303 | All 1 models | 1 | 5 ft equivalent length |
| 3 in Twin Pipe Termination | 3PPS-HTPL | All 1 models | 1 | 10 ft equivalent length |
| 3 in Single Horizontal Termination | 3PPS-HSTL | All 1 models | 1 | 5 ft equivalent length |
| 3 in Black UV Resistant Tee | 3PPS-TBL | All 1 models | 1 | 6 ft equivalent length |
| FGV PVC Low Profile Termination Kit PVC version 196985PVC, order from Rinnai | 196985 | All 1 models | 1 | 5 ft equivalent length |
| FGV PVC Wall Termination Kit | 081219 | All 1 models | 1 | 16 ft equivalent length |
| PVC Side Wall Vent Kit | 52SWVKGVS6503 | All 1 models | 1 | 5 ft equivalent length |
| PVC Wall Vent Kit | 52WTVKGVS6503 | All 1 models | 1 | 16 ft equivalent length |
| 3 in Low Profile Horizontal Vent Kit | HVENT-3 | All 1 models | 1 | 5 ft equivalent length |
| Condensate neutralizer kit Raises condensate pH to help prevent corrosion of the drain and public sewer. Install per neutralizer manual and local codes. | 804000074 | All 1 models | 1 |
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 32 (pages 17, 20, 30, 31, 32, 33, 34, 35, 60). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.