NTI · Boiler · Trinity Tft series

Tft 155-255 parts

56 replacement parts that fit the NTI Tft 155-255, with OEM part numbers, grouped by system.

Controls & boards

PartPart #QtySize / rating
Switch, On-Off (Tft series w/ Touch Screen)
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 41, pp.82-86.
844901
Switch, On-Off (Tft series w/ LCD Dot-Matrix Display)
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 41, pp.82-86.
844221
Trinity Touch Screen Display
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 43, pp.82-86.
835921
LCD Dot-Matrix Display
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 43, pp.82-86.
\-1
Transformer, 24V, 40VA
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 44, pp.82-86.
831901
Controller, Tft series
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 45, pp.82-86.
777771
Terminal, Barrier, 2 Row, 8 Position
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 46, pp.82-86.
844201
Terminal, Barrier, 2 Row, 9 Position
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 47, pp.82-86.
844211
Power Supply – Touch Screen (Tft series w/ Touch Screen Display)
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 51, pp.82-86.
83592-11
Display Support, Galvanized (Tft series w/ Touch Screen Display)
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 86, pp.82-86.
845861
Display Support, Galvanized (Tft series w/ LCD Dot-Matrix Display)
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 86, pp.82-86.
845871
Display Cover (Tft series w/ Touch Screen Display)
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 87, pp.82-86.
845881
Display Cover (Tft series w/ LCD Dot-Matrix Display)
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 87, pp.82-86.
845891

Ignition & flame

PartPart #QtySize / rating
Ignition Electrode, Dual – c/w gasket
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 11, pp.82-86.
838701
Flame Rod Gasket
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 12, pp.82-86.
827741
Flame Rod
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 21, pp.82-86.
827621
Ignition Coil
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 39, pp.82-86.
837071
Spark Igniter Wire, 12"
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 42, pp.82-86.
837241
Spark Generator Support Bracket, Galvanized
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 85, pp.82-86.
845851

Gas valve & orifices

PartPart #QtySize / rating
Gas Valve Regulator Vent Adapter
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 13, pp.82-86.
826001
Natural Gas to LP Conversion Instructions
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 64, pp.82-86.
844921
Natural Gas to LP Conversion Instructions
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 64, pp.82-86.
845011
Conversion Decal
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 65, pp.82-86.
827821
Conversion Decal
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 65, pp.82-86.
844831

Electrical

PartPart #QtySize / rating
Flue Sensor Plug
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 28, pp.82-86.
846371
Fuse, 2A, 32V, Plug Style
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 48, pp.82-86.
835171
Fuse Holder, Panel Mount, 20 Amp at 250VAC Max
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 49, pp.82-86.
841921
Fuse, 7A, 250VAC, Fast-Acting
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 50, pp.82-86.
838371
Receptacle, 120VAC
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 52, pp.82-86.
844231

Inducer & venting

PartPart #QtySize / rating
Grommet, Diaphragm, ½”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 29, pp.82-86.
842141
Dome Plug, 0.875”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 31, pp.82-86.
840951
Plug, 12mm, Flue Adapter Test Port
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 32, pp.82-86.
844971

Water / hydronic

PartPart #QtySize / rating
Supply Pipe, SS, 1”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 18, pp.82-86.
844541
Supply Pipe, SS, 1 ¼”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 18, pp.82-86.
844571
Supply Pipe, SS, 1 ½”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 18, pp.82-86.
844601
Return Pipe, SS, 1”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 19, pp.82-86.
844551
Return Pipe, SS, 1 ¼”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 19, pp.82-86.
844581
Return Pipe, SS, 1 ½”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 19, pp.82-86.
844611
Low Water Cutoff
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 24, pp.82-86.
844241
Sight Glass Assembly
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 25, pp.82-86.
845461
Sensor, Flue, Dual
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 35, pp.82-86.
836081
Snap Bushing, 1”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 40, pp.82-86.
822501
Auto Air Vent, ½” NPT
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 54, pp.82-86.
844741
Pressure Relief Valve, ASME, ¾” NPT, 30psi
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 55, pp.82-86.
137011
Pressure Gauge, 0-30psi
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 56, pp.82-86.
821481
Brass Elbow, 90, Street, ¾”
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 57, pp.82-86.
844791
Outdoor Sensor, 10K
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 62, pp.82-86.
81027-11
System Sensor, 10K
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 63, pp.82-86.
840101
Condensate Trap
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 72, pp.82-86.
829131
Top Heat Exchanger Support, Galvanized
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 76, pp.82-86.
845681
Bottom Heat Exchanger Support, Galvanized
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 77, pp.82-86.
845691

Cabinet & doors

PartPart #QtySize / rating
Lower Wall Mount Bracket
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 71, pp.82-86.
839551
Top Panel
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 73, pp.82-86.
845611
Top Panel Access Cover
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 74, pp.82-86.
845641
Control Panel Base, Galvanized
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 84, pp.82-86.
845841
Control Panel Cover, Galvanized
Replaces / alternate: NTI Trinity Tft60-399 Installation and Operation Manual (2012), Table 16-1 parts list, item 88, pp.82-86.
845901

Same series

The Trinity Tft parts list shows every part for all 21 models side by side. Other models: Tft 110, Tft 155-250, Tft 300-399, Tft 60-110, Tft 60-250, Tft 60-399, Tft 60-85, Tft110, Tft154, Tft155, Tft175, Tft200, Tft201, Tft250, Tft285, Tft300, Tft340, Tft399, Tft60, Tft85.

Source: Included in Kit 82650-1 w/ Tft60-250. Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.