Navien · General · WEC series

WEC600 parts

96 replacement parts that fit the Navien WEC600, with OEM part numbers, grouped by system.

Electrical

PartPart #QtySize / rating
Power board fan300271591
Power board assembly300257881
Power cord
Connected to the power board
300263391
NDI extension harness
Extends the NDI control harness
300267291
Fuse
Included in the power board assembly
200645761
Solenoid valve wire harness
Connects the solenoid valves in this assembly together.
300267311
Sensor harness300267321
Inlet solenoid wire harness300278601

Other

PartPart #QtySize / rating
Drip tray200611341
Stopper200530931
Quick connector3003375011/4 in
Top cover300266261
Right side cover200523551
Left side cover200523541
Front cover200523561
Front display panel kit300406721
Circulation pump300268191
Circulation pump bypass T-adapter3002682011/2 in OD
Circulation pump inlet hose300269121
Circulation pump outlet hose300269141
Solenoid valve300303111DC 24V
Quick connect T-fitting3003030411/4 in
Quick connect L-shape fitting3003056311/4 in
Anti-freeze inlet hose (LLDPE)3003030911/4 in
Anti-freeze outlet hose (LLDPE)3003031011/4 in
Anti-freeze thermistor300305661
CIP hose assembly3002847911/2 in
Side cover caps300328351
CIP hose assembly3002847811/4 in
Quick connect tee nipple FNF 2400 fitting300329481
CIP hose safety fitting300329451
Quick connect tee nipple NFF 3400 fitting300329491
NDI module300340521
Screw (M4x12)200258931M4x12
Screw (4x10)2001908314x10
Screw (4x20)2005725814x20
Screw (5x12)2003468515x12
Nut (M8)200261981M8
Screw (4x8)2000648914x8
Locking clip2005844411/4 in
Locking clip2005843811/2 in
L-Clip20030608126
O-ring (P26)200540091P26
NDI control harness
Connects the NDI modules to the power board
300267271
Pump extension harness
Connects the circulation pump to the power board
300267261
Main harness
Connects the front display panel to the power board
300267301
Chlorine tablet pouch holder kit (3/4 in)
Pouch holder and tablet pouch included
30040223A13/4 in
Chlorine tablet pouch holder kit (1 in)30040072A11 in
Installation start-up kit (sediment, carbon block filter installation kit)300293391
Sediment cartridge filter300309641
Carbon block filter300395951
Chlorine tablet pouch holder kit (3/4")3004022313/4"
Chlorine tablet pouch holder kit (1")3004007211"
Sediment housing mounting bracket & screws300339421
Drain hose assembly (LLDPE, 1/2")3002830911/2"
Quick connect fitting (1/4")3003030211/4"
Tubing hose (1/2", 8.2 ft (2.5 m))2005487611/2", 8.2 ft (2.5 m)
Freeze drain line hose (1/4", 8.2 ft (2.5 m))2005856311/4", 8.2 ft (2.5 m)
CIP bending tubing300332601
Elbow adapter set300328431
Service manual200652961
CIP dosing pump assembly300337511
CIP tank quick connect check fitting (1/4" OD)3003324411/4" OD
CIP tank water level sensor assembly300337521
Decorative film200646841
CIP tank assembly300266081
CIP tank cap300344121
Screw (4x12)2003875514x12
Screw (3x8)2003856913x8
Purified/regeneration water pipe assembly300337561
Solenoid valve (DC 24V, normal close)300263161DC 24V, normal close
Regeneration solenoid valve (DC 24V)300255931DC 24V
Circulation pump solenoid valve (DC 24V, 1/2")300303011DC 24V, 1/2"
Quick connect elbow fitting (1/2" OD)3002687611/2" OD
CIP tank fitting assembly300284851
Flow switch sensor300103991
Outlet adapter (Y-type)200566171Y-type
Screw (4x16)2000655614x16
Screw (4x12)2004146114x12
Outlet sensor cover200641451
Bracket200523421
Check valve300265891
Flow sensor300290901
Water pressure sensor300226721
Silicone connection cap200464111
D-clip (25)20007859125
O-ring (P15)200763351P15
O-ring (P16)200763361P16
Check valve300255921
Rubber inlet & outlet plug kit300398391
Drain connection adapter assembly300337551
CIP inlet inject adapter (1" OD)2006414611" OD
Thermistor300331891
TDS sensor300290861
Quick connect tee fitting (1/2")3002687711/2"
Screw (4x6)2001796214x6

Same series

The WEC parts list shows every part for all 1 models side by side.

Source: Navien WEC service manual, p. 120 (pages 120, 121, 122, 123, 125, 126). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.