Navien · Water heater parts

Navien NWP500: parts list

44 replacement parts with OEM part numbers for 4 models. Pick your model for a list of only the parts that fit it.

Jump to: Electrical · Other

Electrical

PartPart #FitsQtySize / rating
Overload Protector30036800*NWP500 series1
Capacitor20071120*NWP500 series1
Capacitor20071120NWP500-50, NWP500-65, NWP500-801

Other

PartPart #FitsQtySize / rating
Intake Filter20068915*NWP500 series1
Intake Filter Grille20072241*NWP500 series1
Electronic Expansion Valve (EEV) Coil30036215*NWP500 series1
Upper Inlet & Outlet Pipe30036106*NWP500 series1
Fan Assembly30035398*NWP500 series1
Outside Air Temp sensor30038926*NWP500 series1
Water Leak Detection Sensor30031685*NWP500 series1
CT Sensor20071987*NWP500 series1
Energy Cut Off (ECO) Switch30035521*NWP500 series1
Temperature and Pressure (T&P) Relief Valve30036068*NWP500 series1150 psi
Drain Valve30036062*NWP500 series1
Heating Element30036069*NWP500 series1
Control Assembly30036288*NWP500 series1
Fan Assembly Fixing Screw20072676*NWP500 series1
Top Kit Fixing Screw (Side)20072409*NWP500 series1
Main Controller Screw20072408*NWP500 series1
Heating Element Wire Screw20077432*NWP500 series1
Heating Element Case Fixing Screw20072407*NWP500 series1
Navien recirculation pump
BLDC pump with built-in flow and temperature sensors; installs on the system return line. Power adapter supplied.
30040829ANWP500-50, NWP500-65, NWP500-80124 V DC, 3/4 in pipe, 17.7 ft head
O-ring, top pipe upper
Use for the upper top pipe. Damaged or improperly installed O-rings can leak.
P22ANWP500-50, NWP500-65, NWP500-801
O-ring, top pipe lower
Use for the lower top pipe. Damaged or improperly installed O-rings can leak.
P26NWP500-50, NWP500-65, NWP500-801
O-ring, side pipes
Use for the side pipes. Damaged or improperly installed O-rings can leak.
P24NWP500-50, NWP500-65, NWP500-801
Intake Filter20068915NWP500-50, NWP500-65, NWP500-801
Intake Filter Grille20072241NWP500-50, NWP500-65, NWP500-801
Electronic Expansion Valve (EEV) Coil30036215NWP500-50, NWP500-65, NWP500-801
Overload Protector30036800NWP500-50, NWP500-65, NWP500-801
Upper Inlet & Outlet Pipe30036106NWP500-50, NWP500-65, NWP500-801
Fan Assembly30035398NWP500-50, NWP500-65, NWP500-801
Outside Air Temp Sensor30038926NWP500-50, NWP500-65, NWP500-801
Water Leak Detection Sensor30031685NWP500-50, NWP500-65, NWP500-801
CT Sensor20071987NWP500-50, NWP500-65, NWP500-801
Energy Cut Off (ECO) Switch30035521NWP500-50, NWP500-65, NWP500-801
Temperature and Pressure (T&P) Relief Valve30036068NWP500-50, NWP500-65, NWP500-801150 psi
Drain Valve30036062NWP500-50, NWP500-65, NWP500-801
Heating Element30036069NWP500-50, NWP500-65, NWP500-801
Control Assembly30036288NWP500-50, NWP500-65, NWP500-801
Fan Assembly Fixing Screw20072676NWP500-50, NWP500-65, NWP500-801
Top Kit Fixing Screw (Side)20072409NWP500-50, NWP500-65, NWP500-801
Main Controller Screw20072408NWP500-50, NWP500-65, NWP500-801
Heating Element Wire Screw20077432NWP500-50, NWP500-65, NWP500-801
Heating Element Case Fixing Screw20072407NWP500-50, NWP500-65, NWP500-801

Source: NWP500 installation manual, p. 78 (pages 36, 70, 78). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.