Navien · Furnace · NDF series
All parts
42 replacement parts that fit the Navien All, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Inducer, two speed Ref 3. Navien service code 30043621A | W062-0080-SER | 1 | |
| Sensor, flame - replacement Ref 5. Navien service code 30043624A | W010-2562 | 1 | |
| Igniter, HSI - replacement Ref 6. Navien service code 30043625A | W357-0019-SER | 1 | |
| Switch, blower door Ref 7. Navien service code 30043626A | W010-2565 | 1 | |
| Switch, burner rollout Ref 8. Navien service code 30043627A | W010-2568 | 1 | 350 F |
| Transformer, 120 V to 24 V Ref 10. Navien service code 30043630A | W707-0031-SER | 1 | 40 VA |
| Control, integrated ECM Ref 11. Navien service code 30043659A | W190-0173-SER | 1 | |
| Gasket, choke Ref 13. Navien service code 30043656A | W290-0385-SER | 1 | |
| Service kit - conversion NG to LP (#47) Navien service code 30043636A | W370-0258 | 1 | #47 |
| Service kit - conversion LP to NG (#47) Navien service code 30043684A | W370-0259 | 1 | #47 |
| Assy, condensate trap Navien service code 30043655A | W010-2768 | 1 | |
| Valve, two stage Navien service code 30043663A | W010-2573 | 1 | |
| Fuse, 5 A Navien service code 30043660A | W010-2563 | 1 | 5 A |
| Harness, board to upper vestibule Navien service code 30043665A | W750-0232 | 1 | |
| Harness, power board to motor Navien service code 30043667A | W750-0231 | 1 | |
| Harness, signal board to motor Navien service code 30043668A | W750-0233 | 1 | |
| Baggie - Navien NDF Navien service code 30044233A | W020-10010524 | 1 | |
| Clamp, nylon HC672 black Navien service code 30044234A | W155-0009 | 1 | HC672 |
| Clamp, nylon HC875 black Navien service code 30044235A | W155-0010 | 1 | HC875 |
| Fitting, air intake flange Navien service code 30044236A | W255-0062 | 1 | |
| Fitting, 1/2 in tooled 90 degree barb Navien service code 30044237A | W255-0050 | 1 | 1/2 in |
| Fitting, 1/2 in slip, CPVC Navien service code 30044238A | W255-0054 | 1 | 1/2 in |
| Fitting, 5/8 in tooled 90 degree barb XL Navien service code 30044239A | W255-0070 | 1 | 5/8 in |
| Gasket, air inlet adaptor Navien service code 30044240A | W290-0912 | 1 | |
| Gasket, condensate trap Navien service code 30044241A | W290-0879 | 1 | |
| Grommet, pass through 2 in EP Navien service code 30044242A | W315-0106 | 1 | 2 in |
| Grommet, pass through 4 in EP Navien service code 30044243A | W315-0107 | 1 | 4 in |
| Hose, square NS EPDM 60D black Navien service code 30044244A | W345-0011 | 1 | 0.35 in x 0.35 in |
| Tube, 5/8 ID manifold cover drain Navien service code 30044245A | W345-0019 | 1 | 5/8 in ID |
| Cap - BP 7/8 in Navien service code 30044246A | W120-0068 | 1 | 7/8 in |
| Screw #8 x 3/4 in hex drive TEKS Navien service code 30044247A | W570-0056 | 1 | #8 x 3/4 in |
| Plastic, condensate trap Navien service code 30044248A | W497-0004 | 1 | |
| Screw, #8 x 1/2 in hex HD Navien service code 30044249A | W570-0010 | 1 | #8 x 1/2 in |
| Leaflet, installation checklist Navien Navien service code 30044250A | W415-10010525 | 1 | |
| Bracket, trap horizontal mount Navien service code 30044251A | W080-1971 | 1 | |
| Bracket, condensate trap Navien service code 30044252A | W080-1972 | 1 | |
| Gasket, condensate trap Navien service code 30044258A | W290-0160 | 1 | |
| Gasket, downflow mount condensate Navien service code 30044253A | W290-0172 | 1 | |
| Bracket, condensate trap mount Navien service code 30044254A | W080-1240 | 1 | |
| Label, conversion identification Navien service code 30044255A | W385-0921 | 1 | |
| Card, QA checklist Navien service code 30044256A | W122-0435 | 1 | |
| Label, barcode Navien service code 30044257A | W386-10010526 | 1 |
Same series
The NDF parts list shows every part for all 8 models side by side. Other models: 105, 50, 70-3, 70-4, 90, NDF series, NDF600 series.
Source: Navien NDF installation and operation manual, p. 78 (pages 77, 78). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.