Navien · Boiler parts
Navien NCB-H: parts list
19 replacement parts with OEM part numbers for 6 models. Pick your model for a list of only the parts that fit it.
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Gas orifice, NG (0-5,399 ft) Natural gas orifice | 20049500A | NCB-190/060H, NCB-190/080H | 1 | Ø4.50 / Ø6.30 |
| Gas orifice, LP (0-10,100 ft) Factory installed for LP | 20050545A | NCB-190/060H, NCB-190/080H | 1 | Ø3.65 / Ø4.95 |
| Gas orifice, NG (0-5,399 ft) Natural gas orifice | 20049501A | NCB-240/110H, NCB-240/130H, NCB-250/150H | 1 | Ø4.80 / Ø7.50 |
| Gas orifice, LP (0-10,100 ft) Factory installed for LP | 20050546A | NCB-240/110H, NCB-240/130H, NCB-250/150H | 1 | Ø3.90 / Ø5.65 |
| High altitude conversion kit, NG Offset -0.01 in ± 0.01 in | NAC-NH190/080 | NCB-190/060H, NCB-190/080H | 1 | |
| LP conversion kit Offset -0.04 in ± 0.01 in | NAC-L190/080 | NCB-190/060H, NCB-190/080H | 1 | |
| High altitude conversion kit, NG Offset -0.06 in ± 0.01 in | NAC-NH240/130 | NCB-240/110H, NCB-240/130H | 1 | |
| LP conversion kit Offset -0.06 in ± 0.01 in | NAC-L240/130 | NCB-240/110H, NCB-240/130H | 1 | |
| High altitude conversion kit, NG Offset -0.06 in ± 0.01 in | NAC-NH250/150 | NCB-250/150H | 1 | |
| LP conversion kit Offset -0.06 in ± 0.01 in | NAC-L250/150 | NCB-250/150H | 1 | |
| Igniter Gasket Location: igniter. Must be replaced with a new gasket whenever the igniter is reinstalled. Improper assembly can cause gas leakage. | 20051913A | NCB-H series | 1 | |
| O-RING (P18) Location: return pipe. | 20003022A | NCB-H series | 2 | |
| O-RING (P16) Location: water way. | 20048005A | NCB-H series | 1 | |
| Packing Location: water way. | 20047738A | NCB-H series | 2 | |
| Packing Location: pump. | 20044484A | NCB-H series | 1 | |
| Fuse (power wiring) Location: power wiring. | 20042859A | NCB-H series | 1 | 20A |
| Fuse (controller main PCB) Location: controller, main PCB. | 20002934A | NCB-H series | 1 | 3.15A |
| Fuse (controller zone pump) Location: controller, zone pump. | 20002926A | NCB-H series | 1 | 10A |
| Sandpaper (flame rod cleaning) Used to clean the flame rod. | 20033970A | NCB-H series | 1 |
Source: Navien NCB-H LP gas and high altitude conversion guide (pages 1, 2). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.