Lennox · Gas fireplace parts
Lennox Lennox Elite Linear View LDV42/LDV54: parts list
39 replacement parts with OEM part numbers for 6 models. Pick your model for a list of only the parts that fit it.
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Control compartment access panel | H8435 | LDV42, LDV54 | 1 | |
| Control compartment access door gasket | H8436 | LDV42, LDV54 | 1 | |
| Gas train assembly, natural gas | H8796 | LDV42 | 1 | |
| Gas train assembly, natural gas | H8795 | LDV54 | 1 | |
| Gas train assembly, propane | H8798 | LDV42 | 1 | |
| Gas train assembly, propane | H8797 | LDV54 | 1 | |
| Burner assembly | H8794 | LDV42 | 1 | |
| Burner assembly | H8432 | LDV54 | 1 | |
| Remote control handheld transmitter | H8563 | LDV42, LDV54 | 1 | |
| Remote control receiver (wall switch) | H8564 | LDV42, LDV54 | 1 | |
| DFC wire harness | H8601 | LDV42, LDV54 | 1 | |
| Top baffle | H8787 | LDV42 | 1 | |
| Top baffle | H8583 | LDV54 | 1 | |
| Glass door assembly | H8799 | LDV42 | 1 | |
| Glass door assembly | H8431 | LDV54 | 1 | |
| Back panel, black porcelain | H8800 | LDV42 | 1 | |
| Back panel, black porcelain | H8804 | LDV54 | 1 | |
| Side panel RH, black porcelain | H8801 | LDV42 | 1 | |
| Side panel RH, black porcelain | H8805 | LDV54 | 1 | |
| Side panel LH, black porcelain | H8802 | LDV42 | 1 | |
| Side panel LH, black porcelain | H8806 | LDV54 | 2 | |
| Power transformer | H8006 | LDV42, LDV54 | 1 | |
| Floor section, rear | H8790 | LDV42 | 1 | |
| Floor section, rear | H8791 | LDV54 | 1 | |
| Floor section, front | H8792 | LDV42 | 1 | |
| Floor section, front | H8793 | LDV54 | 1 | |
| Battery holder (backup) | H8803 | LDV42, LDV54 | 1 | |
| Ground wire | H7278 | LDV42, LDV54 | 1 | |
| DFC ignition board | H7272 | LDV42, LDV54 | 1 | |
| Gas valve (886), natural gas | H8562 | LDV42, LDV54 | 1 | |
| Gas valve (886), propane | H8594 | LDV42, LDV54 | 1 | |
| Pilot assembly, natural gas | H7268 | LDV42, LDV54 | 1 | |
| Pilot assembly, propane | H7269 | LDV42, LDV54 | 1 | |
| Door latch assembly | H8433 | LDV42, LDV54 | 1 | |
| Flex gas connector assembly | 93L32 | LDV42, LDV54 | 1 | |
| Orifice connector | H7847 | LDV42, LDV54 | 1 | |
| ON/OFF switch | 27K30 | LDV42, LDV54 | 1 | |
| Non-combustible fiber board | H8788 | LDV42 | 1 | |
| Non-combustible fiber board | H8789 | LDV54 | 1 |
Source: Lennox Elite LDV42/LDV54 Installation Instructions 506011-02 (Replacement Parts List). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.