Glow Brand · Boiler parts
Glow Brand C95 & C140: parts list
121 replacement parts with OEM part numbers for 7 models. Pick your model for a list of only the parts that fit it.
Jump to: Electrical · Condensate · Other
Electrical
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Wire harness clip | GLO-67 | C95 & C140 | 1 | |
| Ionization electrode cable | GLO-44 | C95 & C140 | 1 | 585 mm |
| Ignition electrode cable | CB-109 | C95 & C140 | 1 | 1095 mm |
| Terminal strip screw | CB-137 | C95 & C140 | 1 | |
| Electrical control terminal strip | CB-116 | C95 & C140 | 1 | |
| Field wiring strip bracket | C-194-S | C95 & C140 | 1 | |
| Field wiring terminal strip label | C-137 | C95 & C140 | 1 | |
| Display board decal | CB-119 | C95 & C140 | 1 | |
| Silicone cable wire grommet | CB-127 | C95 & C140 | 1 | |
| Display board enclosure | CB-123 | C95 & C140 | 1 | |
| Display board | CB-122 | C95 & C140 | 1 | |
| Display board standoff | CB-110 | C95 & C140 | 1 | |
| NG ignition control board (natural gas only) Natural gas only | CB-121 | C95 & C140 (natural gas) | 1 | |
| LP ignition control board (liquid propane only) LP only | CB-121-LP | C95 & C140 (LP) | 1 | |
| Display board enclosure screws | CB-182 | C95 & C140 | 1 | |
| Strain relief | GLO-180-42 | C95 & C140 | 1 |
Condensate
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| 3/4 in to 1/2 in condensate hose connector | GLO-180-200 | C95 & C140 | 1 | 3/4 in x 1/2 in |
| 1/2 in to 1/2 in plastic condensate fitting | GLO-180-77 | C95 & C140 | 1 | 1/2 in x 1/2 in |
| Hose barb (3/16 in nylon) | GLO-51 | C95 & C140 | 1 | 3/16 in |
| Heat exchanger condensate tube | GLO-180-111 | C95 & C140 | 1 | |
| Condensing trap | GLO-48 | C95 & C140 | 1 | |
| Condensate drain tube | GLO-47 | C95 & C140 | 1 | |
| Condensate hose grommet | GRO-001 | C95 & C140 | 1 | |
| Black polypro barbed tee, 3/16 in | GLO-65 | C95 & C140 | 1 | 3/16 in |
| Silicone condensate hose | GLO-180-22 | C95 & C140 | 1 |
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| High capacity air vent (150 psi) | CB-111 | C95 & C140 | 1 | 150 psi |
| Air vent grommet | CB-126 | C95 & C140 | 1 | |
| Air vent fitting | CB-131 | C95 & C140 | 1 | |
| O-ring for auto air vent | CB-161 | C95 & C140 | 1 | |
| Air vent clip | CB-250 | C95 & C140 | 1 | |
| Flue sensor | GLO-42 | C95 & C140 | 1 | |
| Isothermic ASME H heat exchanger assembly | CB-112 | C95 | 1 | |
| Isothermic ASME H heat exchanger assembly | CB-113 | C140 | 1 | |
| Heat exchanger holding clamp | GLO-60 | C95 & C140 | 1 | |
| 8-32 x 3/8 steel pan Phillips T-screws, type F | GLO-180-103 | C95 & C140 | 1 | 8-32 x 3/8 in |
| Galvanized screen | SCREEN | C95 & C140 | 1 | |
| Zip ties | CB-115 | C95 & C140 | 1 | |
| Cotter pin 1/8 in x 3-1/2 in | CB-148 | C95 & C140 | 1 | 1/8 in x 3-1/2 in |
| Slit tubing | CB-132 | C95 & C140 | 1 | |
| Hinge door | CB-193-S | C95 & C140 | 1 | |
| 3/4 in NPT brass fitting | GLO-180-50-2 | C95 & C140 | 1 | 3/4 in NPT |
| 3/4 in fiber washer for gas pipe | GLO-172 | C95 & C140 | 1 | 3/4 in |
| Gas supply tube | CB-103 | C95 & C140 | 1 | |
| 1/2 in fiber washer for gas pipe | GLO-173 | C95 & C140 | 1 | 1/2 in |
| M4 x 12 hex GV screw | GLO-563 | C95 & C140 | 1 | M4 x 12 |
| GV cork gasket | GLO-170 | C95 & C140 | 1 | |
| Brass boiler GV fitting | CB-130 | C95 & C140 | 1 | |
| Gas valve | GLO-541 | C95 & C140 | 1 | |
| Gas valve rubber coupling | GLO-547 | C95 & C140 | 1 | |
| Gas valve mounting screws | GLO-180-110 | C95 & C140 | 1 | |
| Brass nut | CB-133 | C95 & C140 | 1 | |
| Fan/burner gasket | GLO-50 | C95 & C140 | 1 | |
| Fan | GLO-543 | C95 & C140 | 1 | |
| Fan/venturi O-ring | GLO-544 | C95 & C140 | 1 | |
| Venturi mounting hex screw | GLO-180-109 | C95 & C140 | 1 | |
| Venturi 20 mm | CB-183 | C95 | 1 | 20 mm |
| Venturi 24 mm | CB-184 | C140 | 1 | 24 mm |
| Venturi 20 mm (LP) LP | CB-183-LP | C95 LP | 1 | 20 mm |
| Venturi 24 mm (LP) LP | CB-184-LP | C140 LP | 1 | 24 mm |
| M5 x 12 DIN933-8.8 hex screw | GLO-180-106 | C95 & C140 | 1 | M5 x 12 |
| 10-24 x 1/2 HWH thread cutting screws | GLO-180-104 | C95 & C140 | 1 | 10-24 x 1/2 in |
| Blocked flue switch | GLO-180-150 | C95 & C140 | 1 | |
| Blocked flue switch mounting bracket | GLO-180-21 | C95 & C140 | 1 | |
| Heat exchanger support clamps | CB-114 | C95 | 1 | |
| Heat exchanger support clamps | GLO-59 | C140 | 1 | |
| Front door mounting bracket | GLO-180-S-09 | C95 & C140 | 1 | |
| PVC vent plug (white) PVC | GLO-02-PLUG | C95 & C140 | 1 | |
| CPVC vent plug (grey) CPVC | GLO-03-PLUG | C95 & C140 | 1 | |
| Left panel (painted) | CB-202-S | C95 | 1 | |
| Left panel (painted) | CB-203-S | C140 | 1 | |
| Right panel (painted) | CB-201-S | C95 | 1 | |
| Right panel (painted) | CB-204-S | C140 | 1 | |
| Wrap rear support mounting bracket | CB-192-S | C95 & C140 | 1 | |
| PVC combustion air inlet adapter | GLO-01 | C95 & C140 | 1 | |
| CPVC exhaust flue adapter | GLO-03 | C95 & C140 | 1 | |
| Combi wrap (unpainted) | C-190-S | C95 | 1 | |
| Combi wrap (unpainted) | C-191-S | C140 | 1 | |
| Vent adapter screw | GLO-180-114 | C95 & C140 | 1 | |
| Gear clamp | GLO-180-41 | C95 & C140 | 1 | |
| O-ring | CB-149 | C95 & C140 | 1 | |
| Stainless steel heat exchanger clip | GLO-70 | C95 & C140 | 1 | |
| High limit switch screw | GLO-180-100 | C95 & C140 | 1 | |
| High limit switch (95 deg) | EKA-323-39 | C95 & C140 | 1 | 95 deg |
| REV1 supply tube | CB-106-1 | C140 | 1 | |
| REV1 supply tube | CB-106-2 | C95 | 1 | |
| Hot water 18 mm pipe clip D18 | CB-141 | C95 & C140 | 1 | 18 mm |
| Relief valve fixture | B-117 | C95 & C140 | 1 | |
| Safety pressure relief valve | CB-136 | C95 & C140 | 1 | 30 psi |
| Low loss header | C-118 | C140 | 1 | |
| Expansion tank clip | CB-140 | C95 & C140 | 1 | |
| Central heating block (CHB) assembly | C-101 | C95 & C140 | 1 | |
| 3/4 in rubber washer | GLO-40 | C95 & C140 | 1 | 3/4 in |
| Hot water 18 mm pipe O-ring | CB-143 | C95 & C140 | 1 | 18 mm |
| Heat exchanger inlet tube | C-105 | C95 & C140 | 1 | |
| Temperature clip sensor | GLO-41 | C95 & C140 | 1 | |
| Expansion tank left bottom bracket | C-196-S | C95 & C140 | 1 | |
| Expansion tank right bottom bracket | C-197-S | C95 & C140 | 1 | |
| 3/8 in fiber washer for expansion tank | GLO-171 | C95 & C140 | 1 | 3/8 in |
| Expansion tank copper tube | C-107-1 | C140 | 1 | |
| Expansion tank copper tube | C-107-2 | C95 | 1 | |
| Expansion tank O-ring | CB-142 | C95 & C140 | 1 | |
| Flat expansion tank | CB-135 | C95 & C140 | 1 | |
| Expansion tank top bracket | C-195-S | C95 & C140 | 1 | |
| Combi boiler front door (painted) | CB-200-S | C95 & C140 | 1 | |
| Wall mount support bracket | GLO-180-S-13 | C95 & C140 | 1 | |
| Stainless steel heat exchanger | CB-150 | C95 | 1 | |
| Stainless steel heat exchanger | CB-151 | C140 | 1 | |
| Manual air vent | CB-156 | C95 & C140 | 1 | |
| Flue outlet adapter (60 mm) | GLO-62 | C95 & C140 | 1 | 60 mm |
| Heat exchanger refractory insulation | GLO-180-75 | C95 & C140 | 1 | |
| Cork heat exchanger | CB-159 | C95 & C140 | 1 | |
| Burner plate gasket | GLO-585 | C95 & C140 | 1 | |
| Burner plate refractory insulation | GLO-180-74 | C95 & C140 | 1 | |
| Burner & plate | CB-152 | C95 | 1 | |
| Burner & plate | CB-153 | C140 | 1 | |
| Ignition electrode gasket | GLO-586 | C95 & C140 | 1 | |
| Ignition electrode | GLO-582-1 | C95 & C140 | 1 | |
| Electrode mounting screws | GLO-588 | C95 & C140 | 1 | |
| Ionization electrode | GLO-583 | C95 & C140 | 1 | |
| Ionization electrode gasket | GLO-587 | C95 & C140 | 1 | |
| Burner mounting nuts | GLO-589 | C95 & C140 | 1 |
Source: Glow Brand C95 & C140 Installation & Operating manual, p. 86 (pages 84, 86, 87, 88). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.