Carrier · Heat pump parts
Carrier D5CMHA: parts list
13 replacement parts with OEM part numbers for 6 models. Pick your model for a list of only the parts that fit it.
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Base pan rubber plug Quantity per unit. Listed as RCD part number. | 12600801A00117 | 18K, 24K | 5 | |
| Base pan rubber plug Quantity per unit. Listed as RCD part number. | 12600801A00077 | 30K, 36K | 28 | |
| Base pan rubber plug Quantity per unit. Listed as RCD part number. | 12600801A00118 | 48K, 55K | 5 | |
| Compressor (rotary, inverter) ESTER OIL, VG74, 20.97 fl oz oil charge | KTM240D46UKT2 | 18K | 1 | 16309/25931 Btu/h; 805/2045 W input; RLA 4.15/9.30 A |
| Compressor (twin-rotary, inverter) ESTER OIL, VG74, 33.82 fl oz oil charge | KTF310D43UMT | 24K | 1 | 34154 Btu/h; 2765 W input; RLA 5.38 A |
| Compressor (inverter) ESTER OIL, VG75, 49.37 fl oz oil charge | EKPQ420D1UMUA | 30K, 36K | 1 | 40944 Btu/h; 3265 W input; RLA 6.6 A |
| Compressor (inverter) ESTER OIL, VG75, 43.96 fl oz oil charge | EKPQ440D1UMUB | 48K, 55K | 1 | 42786 Btu/h; 3430 W input; RLA 7.3 A |
| Single fan DC motor Speeds 800/700/650 (18K) and 800/750/600 (24K); IPX4 | ZKFN-120-8-9 | 18K, 24K | 1 per fan | 120 W output; 1.2 A FLA; 0.16 HP; 800 rev/min rated |
| Single fan DC motor Speeds 750/700/650; IP44 | ZKFN-250-10-1 | 30K, 36K | 1 per fan | 250 W output; 2.6 A FLA; 0.34 HP; 750 rev/min rated |
| Single and dual fan DC motor Speeds 800/700/650; IP44 | ZKFN-85-10-1L | 48K, 55K | 1 per fan | 85 W output; 2.5 A FLA; 0.16 HP; 800 rev/min rated |
| Propeller fan blade Acrylonitrile Styrene +20%GF | ZL-560*139*12-3KN | 18K, 24K | 1 per fan | 22.0 in (560 mm) dia x 5.5 in (139 mm) high |
| Propeller fan blade Acrylonitrile Styrene +20%GF | ZL-570*196*15-3N | 30K, 36K | 1 per fan | 22.4 in (570 mm) dia x 7.7 in (196 mm) high |
| Propeller fan blade Acrylonitrile Styrene +20%GF; dual fan chassis on 48K and 55K | ZL-554*148*12-3KFN | 48K, 55K | 1 per fan | 21.8 in (554 mm) dia x 5.8 in (148 mm) high |
Source: Carrier D5CMHA product data, p. 10 (pages 4, 10). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.