Allied · Furnace parts

Allied A95/A93/95G1/92G1UH: parts list

24 replacement parts with OEM part numbers for 30 models. Pick your model for a list of only the parts that fit it.

Jump to: Condensate · Other

Condensate

PartPart #FitsQtySize / rating
Condensate heat cable kit, 6 ft
For freeze protection of trap and line
26K68A95/A93/95G1/92G1UH16 ft (1.8 m)
Condensate heat cable kit, 24 ft
For freeze protection of trap and line
26K69A95/A93/95G1/92G1UH124 ft (7.3 m)
Condensate heat cable kit, 50 ft
For freeze protection of trap and line
26K70A95/A93/95G1/92G1UH150 ft (15.2 m)

Other

PartPart #FitsQtySize / rating
Flush-mount termination kit
Provided with 1-1/2 in. accelerator; required for 45,000 and 70,000 Btuh installs
51W11045, 0701
1-1/2 in. concentric kit
44W92 includes 1-1/2 in. accelerator for 045 and 070
71M80 or 44W92045, 070, 090, 110, 13511-1/2 in.
2 in. concentric kit69M29 or 44W92045, 070, 090, 110, 13512 in.
3 in. concentric kit60L46 or 045045, 070, 090, 110, 13513 in.
Direct vent roof termination kit
Used when required for direct vent roof termination
15F75 or 44J41Not specified on these pages1 kit
Direct vent concentric wall termination kit
Includes 1-1/2 in accelerator on 71M80 and 44W92
71M80, 69M29 or 60L46 (US); 44W92 or 44W93 (Canada)A95/A93/95G1/92G1UH1
Non-direct vent roof termination kit
Use with non-direct vent roof termination, 12 in above average snow
15F75 or 44J41A95/A93/95G1/92G1UH1
Natural to LP/propane burner orifice kit
Requires gas valve regulator spring from kit. LP kits include low line pressure switch.
68W75All1
LP/propane to natural burner orifice kit
Requires gas valve regulator spring from kit.
73W80All1
High altitude natural burner orifice kit51W01All1
High altitude LP/propane burner orifice kit
Requires gas valve regulator spring from kit. LP kits include low line pressure switch.
68W70All1
Combustion air pressure switch, 7,501 to 10,000 ft74W91All17,501 to 10,000 ft
Combustion air pressure switch, 045 at 7,501 to 10,000 ft74W90-04517,501 to 10,000 ft
Combustion air pressure switch, 4,501 to 7,500 ft77W43-070, -11014,501 to 7,500 ft
Combustion air pressure switch, 4,501 to 7,500 ft77W42-090, -13514,501 to 7,500 ft
Combustion air pressure switch, 7,501 to 10,000 ft73W22-070, -090, -110, -13517,501 to 10,000 ft
Pressure switch kit, altitude
Shown in the 7,501 - 10,000 ft column for the All row.
74W91A95UH1D / 95G1UH17,501 - 10,000 ft
Pressure switch kit, altitude74W90A93UH1D / 92G1UH 04517,501 - 10,000 ft
Pressure switch kit, altitude73W22A93UH1D / 92G1UH 070, 090, 110, 13517,501 - 10,000 ft
Pressure switch kit, altitude77W43A93UH1D / 92G1UH 070, 11014,501 - 7,500 ft
Pressure switch kit, altitude77W42A93UH1D / 92G1UH 090, 13514,501 - 7,500 ft

Source: Allied 92G1UH installation manual, p. 48 (pages 30, 33, 34, 35, 48). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.