Allied · Furnace parts
Allied A95/A93/95G1/92G1UH: parts list
24 replacement parts with OEM part numbers for 30 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Condensate · Other
Condensate
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Condensate heat cable kit, 6 ft For freeze protection of trap and line | 26K68 | A95/A93/95G1/92G1UH | 1 | 6 ft (1.8 m) |
| Condensate heat cable kit, 24 ft For freeze protection of trap and line | 26K69 | A95/A93/95G1/92G1UH | 1 | 24 ft (7.3 m) |
| Condensate heat cable kit, 50 ft For freeze protection of trap and line | 26K70 | A95/A93/95G1/92G1UH | 1 | 50 ft (15.2 m) |
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Flush-mount termination kit Provided with 1-1/2 in. accelerator; required for 45,000 and 70,000 Btuh installs | 51W11 | 045, 070 | 1 | |
| 1-1/2 in. concentric kit 44W92 includes 1-1/2 in. accelerator for 045 and 070 | 71M80 or 44W92 | 045, 070, 090, 110, 135 | 1 | 1-1/2 in. |
| 2 in. concentric kit | 69M29 or 44W92 | 045, 070, 090, 110, 135 | 1 | 2 in. |
| 3 in. concentric kit | 60L46 or 045 | 045, 070, 090, 110, 135 | 1 | 3 in. |
| Direct vent roof termination kit Used when required for direct vent roof termination | 15F75 or 44J41 | Not specified on these pages | 1 kit | |
| Direct vent concentric wall termination kit Includes 1-1/2 in accelerator on 71M80 and 44W92 | 71M80, 69M29 or 60L46 (US); 44W92 or 44W93 (Canada) | A95/A93/95G1/92G1UH | 1 | |
| Non-direct vent roof termination kit Use with non-direct vent roof termination, 12 in above average snow | 15F75 or 44J41 | A95/A93/95G1/92G1UH | 1 | |
| Natural to LP/propane burner orifice kit Requires gas valve regulator spring from kit. LP kits include low line pressure switch. | 68W75 | All | 1 | |
| LP/propane to natural burner orifice kit Requires gas valve regulator spring from kit. | 73W80 | All | 1 | |
| High altitude natural burner orifice kit | 51W01 | All | 1 | |
| High altitude LP/propane burner orifice kit Requires gas valve regulator spring from kit. LP kits include low line pressure switch. | 68W70 | All | 1 | |
| Combustion air pressure switch, 7,501 to 10,000 ft | 74W91 | All | 1 | 7,501 to 10,000 ft |
| Combustion air pressure switch, 045 at 7,501 to 10,000 ft | 74W90 | -045 | 1 | 7,501 to 10,000 ft |
| Combustion air pressure switch, 4,501 to 7,500 ft | 77W43 | -070, -110 | 1 | 4,501 to 7,500 ft |
| Combustion air pressure switch, 4,501 to 7,500 ft | 77W42 | -090, -135 | 1 | 4,501 to 7,500 ft |
| Combustion air pressure switch, 7,501 to 10,000 ft | 73W22 | -070, -090, -110, -135 | 1 | 7,501 to 10,000 ft |
| Pressure switch kit, altitude Shown in the 7,501 - 10,000 ft column for the All row. | 74W91 | A95UH1D / 95G1UH | 1 | 7,501 - 10,000 ft |
| Pressure switch kit, altitude | 74W90 | A93UH1D / 92G1UH 045 | 1 | 7,501 - 10,000 ft |
| Pressure switch kit, altitude | 73W22 | A93UH1D / 92G1UH 070, 090, 110, 135 | 1 | 7,501 - 10,000 ft |
| Pressure switch kit, altitude | 77W43 | A93UH1D / 92G1UH 070, 110 | 1 | 4,501 - 7,500 ft |
| Pressure switch kit, altitude | 77W42 | A93UH1D / 92G1UH 090, 135 | 1 | 4,501 - 7,500 ft |
Source: Allied 92G1UH installation manual, p. 48 (pages 30, 33, 34, 35, 48). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.