Rinnai · Wall furnace

Lock Control panel lock indicator

Menu / mode display EX DT

What the display is showing

The lock indicator lights and a beep sounds when the control lock is turned on. If the furnace is on, all controls except OFF are locked; if it is off, all controls are locked and it cannot be turned on until the lock is released.

Applies to: Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces

What to do

  1. Press Lock to activate.
  2. Hold Lock for about 2 seconds to release; the indicator goes out and a beep sounds.

Settings for these units

Clearances to combustibles and service · EX DT

LocationClearance
Top0 in. (0 mm)
Bottom / ground0 in. (0 mm)
Front (panel)40 in. (1 m) - flooring or carpet under 1.2 in. (30 mm) high not included
Back (including back spacer)0 in. (0 mm)
Sides (left and right)2 in. (50 mm)
Service access10 in. (254 mm) sides; 40 in. (1 m) front; area above per figure
Exhaust extension pipe1 in. (25.4 mm) to combustibles; 0 in. to non-combustibles

Rinnai recommends 10 in. (254 mm) at top and both sides for servicing.

Service clearance figure above the unit: 10 in. (254 mm) on EX08DT/EX11DT, 9 in. (229 mm) on EX17DT/EX22DT.

Models that show this code

5 models in EX DT

EX08DTEX11DTEX17DTEX22DTEX22DT-W

Other codes on the same units

  • Economy Economy indicator lit
  • FILTER Filter lamp flashing red (air filter blocked)
  • H Set temperature H (maximum burner output)
  • L Set temperature L (minimum burner output)
  • ON lamp green ON indicator green (powered, burner not lit)
  • ON lamp red ON indicator red (burner lit)
  • PH High-fire gas pressure setting mode
  • PL Low-fire gas pressure setting mode

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai EX08DT/EX11DT Installation and Operation Manual (200000083) and EX17DT/EX22DT (200000084), Lock p.31. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.