Napoleon · Gas fireplace

LCD Blinking Remote transmitter display blinking after battery install

Menu / mode display Remote control (transmitter and receiver)

What the display is showing

The transmitter screen blinks right after fresh batteries go in. This marks the code-learning window and is normal. Pressing any button during the blinking sends the code switch setting to the receiver.

Applies to: Napoleon fireplaces with millivolt remote receiver

What to do

  1. Set the code switch on the transmitter before the batteries go in.
  2. Put the receiver switch in the remote position.
  3. Install the batteries and stay about 5 feet from the fireplace.
  4. Press any button while the screen is blinking.
  5. The receiver gives one beep when it has learned the code; repeat if no beep.

Settings for these units

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Napoleon/Wolf Steel Service Manual W415-0118, Troubleshooting: Other Issues - Remote Control Guide, p.30. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.