Midea furnace error codes

14 codes with causes and test steps.

CodeMeaningSeverity
E1Low-fire pressure switch stuck closedHigh
E2Low pressure switch stuck openHigh
E3High pressure switch stuck openHigh
E4Pressure switch cycle lockoutHigh
E5Limit/rollout switch open less than 5 minutesHigh
E6Limit/rollout switch open more than 5 minutesCritical
E7System lockout - failed ignitionHigh
E8System lockout - too many flame dropoutsHigh
LED2 green 1 flashRefrigerant leak sensor communication failureHigh
LED2 green 2 flashesRefrigerant concentration above alarm limit (leak)Critical
LED2 green 3 flashesSensor connected but SW1-2 OFF (DIP reminder)Low
LED2 green 4 flashesRefrigerant sensor expired or faultyHigh
FLLow flame signalMedium
PrIncorrect polarity of L1/L2Medium

Models covered

BGH96M060B3ABGH96M080B3ABGH96M080C4ABGH96M100C5ABGH96M100D5ABGH96M120D5A

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.