Gree · Heat pump
Heat lamp 10 s on / 0.5 s off Defrosting (heating lamp pattern)
What the display is showing
During defrosting in heating mode, the heating lamp stays off for 0.5 s and then blinks for 10 s (the Sapphire manual) or is on for 10 s and off for 0.5 s (the Vireo compulsory-defrost text). The temperature display can show H1 at the same time. Normal operation: the compressor keeps running while the indoor fan stops.
Applies to: Gree Sapphire 9-24k (SAP..HP230V1A); Vireo GEN3 9-24k (3VIR..HP115/230V1A)
Models that show this code
10 models in Gree Sapphire, Gree Vireo GEN3
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 6.2 (10) Display, double-8 display; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 6.2 (10) Display, double-8 display; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 6.2 (9) compulsory defrosting function. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.