Daikin · General

Odor lamp blinking with 3 long beeps Carbon filter unit or carbon filter not seated

Medium severity Daikin Air Purifier

What the control is telling you

On start-up the odor sensor lamp blinks and the unit sounds 3 long beeps. This means the carbon filter unit and/or carbon filter are not properly installed.

Applies to: MCB50YSAU

Likely causes

  • Carbon filter unit not fully pushed in
  • Carbon filter not caught under the fixed parts or hooks

Test and repair steps

  1. Stop operation and unplug the unit.
  2. Remove the carbon filter unit and check the carbon filter is under the 3 fixed parts and the 2 hooks.
  3. Reinstall the carbon filter unit until it clicks.
  4. Plug in and start the unit again; confirm the lamp no longer blinks.

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Daikin Air Purifier installation & operation manual, p. 12. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.