Bosch · Tankless water heater
A1 Cabinet air temperature above 158 F (70 C)
What the control is telling you
The unit is reducing power because the air inside the cabinet is too hot.
Applies to: Bosch Greentherm T9800 SE 160/199 and T9900 SE 160/199 / i 199 tankless water heaters
Likely causes
- Ambient air above 140 F (60 C)
- Flue gas leaking inside the cabinet or concentric vent
Test and repair steps
- Check room temperature around the unit.
- Look for flue leaks inside the appliance or in the concentric vent.
Models that show this code
6 models in Bosch Greentherm T9800 SE, Bosch Greentherm T9900 SE
Other codes on the same units
- A0 Water temperature sensors disconnected or damaged
- A2 External water temperature sensor / aquastat fault
- A3 Flue gas temperature sensor fault
- A4 Air temperature sensor fault
- A5 Condensing unit flue temperature sensor fault
- A6 Inlet cold water temperature sensor fault
- A7 Heat exchanger hot water temperature sensor fault
- A8 Outlet hot water temperature sensor fault
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greentherm T9800 SE 160/199 installation 6720816815 (06.2023), Table 24 Error code diagnostics, p.65-69; Bosch Greentherm T9900 SE 160/199 | i 199 installation 6 720 813 635 (2024-06), section 9.1 Error code diagnostics, p.68-73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.