34 Ignition proving failure

High severity

What the control is telling you

Flame was not sensed after the gas valve opened.

Applies to: Carrier/ICP-family two-digit status codes — confirm with the code label on the unit

Likely causes

  • Dirty flame sensor
  • Poor burner ground
  • Low gas pressure
  • Incorrect polarity

Test and repair steps

  1. Clean the flame sensor
  2. Check flame signal microamps
  3. Verify line voltage polarity and ground
  4. Check gas pressure

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Carrier/ICP status code label — verify per model. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.